Electrical Testing & Diagnostics
Bestcor tests and diagnoses electrical assets — transformers, switchgear, power cables and instrument transformers — with troubleshooting and replacement where applicable.

What we do
Testing and diagnostics verify the condition of your critical electrical assets.
Bestcor specializes in the testing, troubleshooting and maintenance of critical power equipment — including electrical testing of transformers, switchgear, power cables and instrument transformers to confirm performance and safety. Where testing identifies a defective component, replacement is carried out where applicable to restore the installation to service.
Testing, troubleshooting and maintenance of critical power equipment — transformers, switchgear, power cables and instrument transformers.
Problems we help address
- Equipment condition is not always evident from how a plant is running. Electrical testing measures the assets directly, so maintenance and replacement decisions can rest on results rather than on assumption.
- Transformers, switchgear, power cables and instrument transformers that have not been tested leave an open question about their present condition.
- Troubleshooting an electrical fault requires the affected item to be identified before a repair path can be chosen.
- Where a component is found to be defective, the practical question is whether it can be repaired or has to be replaced.
How we approach the work
- The test inventory covers the measurements these asset classes call for, as separate instruments rather than one general-purpose set.
- It includes insulation resistance, insulation power factor and DC high-potential testing; winding resistance and turns ratio on transformers; contact resistance and breaker timing on switchgear; relay testing; and current-transformer and potential-transformer analysis.
- Transformer oil is handled as part of the same work — dielectric breakdown testing and high-vacuum oil purification are both in the test inventory.
- Switchgear condition is checked beyond electrical measurement, including SF6 gas analysis and partial-discharge detection.
- Site measurement also covers grounding resistance, phase sequence, primary current injection, power quality, ultrasonic and thermal scanning, and gas detection.
Why it matters
- Testing gives a measured basis for maintenance and replacement planning: an asset whose condition has been tested can be scheduled, repaired or replaced on evidence.
- Because testing, troubleshooting and repair or replacement sit with the same provider, a test finding does not have to be handed to another party before it can be acted on.
- Relay protection, metering and instrument transformers sit in the same protection chain as the switchgear they work with, so assessing them alongside the primary equipment keeps that chain assessed as a whole.
Systems and equipment covered
- Transformers
- Switchgear
- Power cables
- Instrument transformers
- Troubleshooting and diagnostics
- Replacement where applicable
Capability areas
Related service lines
The same systems also appear in Bestcor's other published service lines.